Shenzhen Eurostars Technology Co., Ltd.
Shenzhen Eurostars Technology Co., Ltd.

MORE

Vegetables Keep Fresh Cod Storage in Kuwait

(1) Cold storages size: 12 x 15 x 5 m (2) Required room temperature: 3~4 degree centigrade (3) Power supply and refrigerant: 415V-3phase-50HZ; R404a (4) Ambient temperature: In summer, min temp 30 degree centigrade, average 40 & max. 52 degree centigrade

MORE

Water Cooled Packaged Air Conditioners For Cambodia Hotel

Vietnam customer requires central air conditioner solution to replace the old air conditioning system for the hotel in Cambodia, prefer to scroll compressor, and refrigerant gas R410A, needs cooling all year round.

MORE

Milk holding Cold Room for Bakery in Australia

(1)Cold storages size: 4 x 4 x 2.4 m (2)A separate condensing units and evaporators (3)Power supply and refrigerant: 220V-1phase-50HZ; R404a (4)Cold room quantity=2nos,need independent control

MORE

Fan Coil Units For Croatia Client

Croatia client company is in the field of shipbuilding and need fan coil units for their new office building, to equip with their heat pump, client wants Modbus function for all fan coils, and group control for cassette ceiling fan coils, all fan coils require air filter, and water drainage, room temperature for cooling mode 27℃, water flow/return for cooling mode 7/12℃; room temperature for heating mode 20℃, water flow/return for heating mode 45/40℃:

MORE

Wine Fermentation Cold Storage in Australia

(1) Cold storage size: 4.5m on length , width 2.7m, and the height is 2.6 m (2) Required room temperature: keep 4 barrels x 200 L of wine, need the temperature between 5 and 12 degree for around 4 months (3) Power supply and refrigerant: 240V-1phase-50HZ; R404a (4) Temperature in summer is around 24 degree and on winter 18 degree

MORE

Blast Freezer for Cooling Fruit Juices in Guatemala

(1) Cold storages size: 7 mt x 2.5mt ( w x l ), Qty=2nos (2) Required temperature: evaporative temperature is -34.5 degrees Celsius (3) Power supply and refrigerant: 460V-3phase-60HZ; R404a (4) Ambient temperature: 37.8 degree centigrade  (5) Storage: quantity of barrels:  54 ( 55 gals each )

MORE

Central Air Conditioner Solution For Portugal Customer

Considering easy installation and not very cold in winter, we suggest our standard air source heat pump, cooling and heating, and our customer company mainly manufacture electronics, we adopt rotary wheel heat recovery inside AHU, and EC fan motor for energy saving, 100% fresh air conditions.

MORE

Eurostars Chillers Application For Shield Tunneling Machines

The 21st century is a century of rapid technological development. The global population has exceeded 6 billion, and the shortage of land resources has increasingly become the focus of attention of all countries. The usage of underground space will be paid more attention. Our country's tunnel construction has achieved a leap-forward development in recent years. Up to 2019, 56 cities in mainland China have a total line of 6,902 kilometers under construction. Among the 6,902 kilometers of construction lines, the underground line is 5632 kilometers, accounting for 81.6%. The annual demand for chillers in this market is estimated to be 5 million dollars.

MORE

14 Tons Tuna Meat Cold Storage in Peru

(1) Cold storages size: 6.5 mt x 6.5mt x 2.5 mts  ( w x l x h), (2) Required temperature: 2 degrees Celsius (3) Power supply and refrigerant: 440V-3phase-60HZ; R404a (4) Ambient temperature: 27 degree centigrade, max is30 degree centigrade (5) Storage: 14 tons tuna meat from 25°C to2°C.

MORE

Refrigeration Solutions For Peru Customer

Required cooling air for chicken meat cold chain inside cold room. Customer required cold room temperature keep 0~5℃, cold room size (L*W*H) 8*3.7*3 meters, there will be 2300 chickens entering into the cold room by chains, and will leave 20 minutes later, with chicken weight 2.4 kg per each, chicken temp. 38℃, and decreased to 20℃ when leaving the cold room.

MORE

Mangoes Cold Storage in Guatemala

Mangoes cold storage information: (1) Cold storages size: Internal dimensions 5.40 mt x 11.70 mt x 03 mts ( w x l x h ), 2 rooms;

MORE

Air Cooled Industrial Chiller For Yemen Customer

Customer required chiller supply 5~15℃ chilled water to their tube mills machine. Considering the water from machine tank has little oil, can not be entered into our chiller directly, water to water gasket heat exchanger becomes necessary. Data for gasket heat exchanger: hot side: water in/out 30C/20C, water flow 18m³/h; cold side: water in/out 18C/20C.