Shenzhen Eurostars Technology Co., Ltd.
Shenzhen Eurostars Technology Co., Ltd.

MORE

Cold Room Condensing Units Installed In Indonesia

Indonesia customer wants to adopt condensing units and air coolers for their starred hotel kitchen project. There are total 14 cold rooms, divided into 4 freezer rooms requiring room temp. -20℃, and 10 chiller rooms requiring room temp. 0~5℃, for storage of meat, fish, vegetables, wet garbage, wine, Sushi, etc. Customer required environmental friendly refrigerant, power supply 380V-3PH-50HZ.  

MORE

Packaged Air Conditioning for Pharmacy Factory In Argentina

(1)Air flow: 3,000 m3 / h,Return flow: 2400 m3 / h, Outdoor air flow: 600 m3 / h (2)Total pressure: 800 Pa (3)Serpentine direct expansion of 15,000 frig / h (4)FILTER CLASS: G4 (MERV8) / PLEATED

MORE

Air Cooled Screw Inverter Chiller Designed For Kenya Plastics Plant

Kenya customer wants to equip industrial chiller for their 2 HDPE 300kg per hour lines and 2 PPR lines 300kg, total 1200Kg, they have a tank with 75 meters cubic, required chilled water outlet temp. 12℃, ensure enough cooling efficiency, working ambient temp. maximum is 25℃. Bitzer compressor is prior choice, and to save energy, they prefer to VFD(variable frequency driver) with Siemens PLC controller.   

MORE

Condensing Units & Evaporators for Chicken Cold Storage in Mexico

(1) Cold storages size: 19m(L) x13.5m(W) x 3 m(H),Room Qty=12 (2) Required room temperature: -2 degrees Celsius, chicken temp before into the cols room 10 degrees Celsius (3) Power supply and refrigerant: 460V-3phase-60HZ; R404a (4) Ambient temperature: 35 degree centigrade  (5) Storage: 7tons of chicken per day

MORE

Direct Expansion Air Handling Units For Korean Project

Korean customer wants to equip direct expansion AHUs and chilled water AHUs for ex-proof outdoors air conditioners with ex-proof compressor for offshore project. AHUs will be installed for many locations on the deck, including CER, CCR, mess room, UPS room, SCR room, FWD Store, Mechanical workshop, Production laboratory, General store, Main store, ER store, Electrical & Instrument workshop, etc. Outdoor units compressor refrigerant is R134A, DX heat exchanger should be suitable for this refrigerant, and AHU should be ceiling mounted installation type, M5 pre-filter, and has noise requirement, no more than 60db(a).  

MORE

Air Cooled Seawater Chiller For Chile Customer

Chile customer wants to cool the water in their salt water tank where keep king crabs alive before being exported. Usually the water there is between 15 ℃ and 20 ℃, he requires to be able to lower the water temperature down to 1℃ for a water about 25,000 liters at first. Seawater flow about 5000 l/h, with a digital temperature control and the appropriate probes to install in the pools.

MORE

Industrial Water Chillers for Plastic Factory in Tanzania

(1)Cold water temperature request: 10~15℃ (2)Cooling capacity:280KW (3)Air cooling mode (5)Power supply:415V-3phase-50HZ (6)Refrigerant:R407C (7)Ambient temperature:21℃~35℃

MORE

Air Cooled Scroll Chiller Installed In Suriname

Suriname customer has own hatchery, they have 7 breeding rooms and 2 batch rooms. Customer requires chilled water to cool down the 1800 liters water that enters into the incubation machines, as the tubes of the incubator have a heater inside and very hot, The chiller water inlet temp. should be 25℃, water outlet temp. 8℃, looking for a chiller with 3 compressors, high efficient shell tube evaporator and high performance water pump.

MORE

Purified Precision AC for Dust-free Electronics Factory in Viet Nam

(1)Temperature request: 18~22℃ (2)Humidity request:50~60% (3)Dust-free require (4)Prefer water cooling unit (5)Power supply:380V-3phase-50HZ (6)Cooling Capacity: based Eurosatrs calculation it needs 180KW

MORE

Air Cooled Modular Heat Pumps & Cassette Fan Coils For Hungary

Hungary customer requires air conditioning and terminals for their factory office building. They want to replace existing cooler that is old technology running with R407 type liquid gas and expect a new A/C cooler for a 6 floor office building of 3000㎡. Client pay the most attention to are the AC system energy saving and stable operation.

MORE

200 Tons Potatoes Cod Storage in Georgia

(1) Cold storages size: 18m(L) x 9.4 m(W)x3.05m(H) and 15m(L) x 9.4 m(W)x3.05m(H) (2) Required room temperature: room temperature should be maintained + 2  + 5 degrees, initial temperature is 7-10 degrees (3) Power supply and refrigerant: 380V-3phase-50HZ; R404a (4) Ambient temperature: 30 degree centigrade, In winter the outside temperature -15-20 degrees. Spring the outside temperature + 15 + 20 degrees. (5) Storage: 200tons of Potatoes

MORE

Air Cooled Bitzer Condensing Units & Evaporators For Peru Company

Peru customer requires refrigeration condensing unit and evaporators for their enabling tunnel chambers and finished products chamber. Inside the enabling tunnel chambers, there are ham cars, sausage pallets, required cooling from 60℃ down to 20℃, total; there will be ham and sausage insides the finished product chamber, required from 6~7C to 0~4C, door openings times and lasting time, product weight, chamber sizes are all provided. Client prefers Bitzer compressor, refrigerant R507A.